[ Upstream commit
35f165f08950a876f1b95a61d79c93678fba2fd6 ]
Almost all fault/warning bits in pmbus status registers remain set even
after fault/warning condition are removed. As per pmbus specification
these faults must be cleared by user.
Modify hwmon behavior to clear fault/warning bit after fetching data if
fault/warning bit was set. This allows to get fresh data in next read.
Signed-off-by: Vikash Chandola <vikash.chandola@linux.intel.com>
Link: https://lore.kernel.org/r/20220222131253.2426834-1-vikash.chandola@linux.intel.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Sasha Levin <sashal@kernel.org>
pmbus_update_sensor_data(client, s2);
regval = status & mask;
+ if (regval) {
+ ret = pmbus_write_byte_data(client, page, reg, regval);
+ if (ret)
+ goto unlock;
+ }
if (s1 && s2) {
s64 v1, v2;