ALSA: doc: ReSTize serial-u16550.txt
authorTakashi Iwai <tiwai@suse.de>
Thu, 10 Nov 2016 16:33:12 +0000 (17:33 +0100)
committerTakashi Iwai <tiwai@suse.de>
Thu, 10 Nov 2016 21:33:29 +0000 (22:33 +0100)
Yet another simple conversion from a plain text file.
Put to cards directory.

Signed-off-by: Takashi Iwai <tiwai@suse.de>
Documentation/sound/cards/index.rst
Documentation/sound/cards/serial-u16550.rst [moved from Documentation/sound/alsa/serial-u16550.txt with 92% similarity]

index b143eff..976ef5e 100644 (file)
@@ -15,3 +15,4 @@ Card-Specific Information
    bt87x
    maya44
    hdspm
+   serial-u16550
similarity index 92%
rename from Documentation/sound/alsa/serial-u16550.txt
rename to Documentation/sound/cards/serial-u16550.rst
index c191955..197aeac 100644 (file)
@@ -1,14 +1,14 @@
-
-                       Serial UART 16450/16550 MIDI driver
-                       ===================================
+===================================
+Serial UART 16450/16550 MIDI driver
+===================================
 
 The adaptor module parameter allows you to select either:
 
-  0 - Roland Soundcanvas support (default)
-  1 - Midiator MS-124T support (1)
-  2 - Midiator MS-124W S/A mode (2)
-  3 - MS-124W M/B mode support (3)
-  4 - Generic device with multiple input support (4)
+* 0 - Roland Soundcanvas support (default)
+* 1 - Midiator MS-124T support (1)
+* 2 - Midiator MS-124W S/A mode (2)
+* 3 - MS-124W M/B mode support (3)
+* 4 - Generic device with multiple input support (4)
 
 For the Midiator MS-124W, you must set the physical M-S and A-B
 switches on the Midiator to match the driver mode you select.
@@ -22,11 +22,13 @@ substream. The driver provides no way to send F5 00 (no selection) or to not
 send the F5 NN command sequence at all; perhaps it ought to.
 
 Usage example for simple serial converter:
+::
 
        /sbin/setserial /dev/ttyS0 uart none
        /sbin/modprobe snd-serial-u16550 port=0x3f8 irq=4 speed=115200
 
 Usage example for Roland SoundCanvas with 4 MIDI ports:
+::
 
        /sbin/setserial /dev/ttyS0 uart none
        /sbin/modprobe snd-serial-u16550 port=0x3f8 irq=4 outs=4
@@ -37,6 +39,7 @@ all four MIDI Out connectors.  Set the A-B switch and the speed module
 parameter to match (A=19200, B=9600).
 
 Usage example for MS-124T, with A-B switch in A position:
+::
 
        /sbin/setserial /dev/ttyS0 uart none
        /sbin/modprobe snd-serial-u16550 port=0x3f8 irq=4 adaptor=1 \
@@ -47,6 +50,7 @@ the outs module parameter is automatically set to 1. The driver sends
 the same data to all four MIDI Out connectors at full MIDI speed.
 
 Usage example for S/A mode:
+::
 
        /sbin/setserial /dev/ttyS0 uart none
        /sbin/modprobe snd-serial-u16550 port=0x3f8 irq=4 adaptor=2
@@ -63,6 +67,7 @@ at most one byte every 520 us, as compared with the full MIDI data rate of
 one byte every 320 us per port.
 
 Usage example for M/B mode:
+::
 
        /sbin/setserial /dev/ttyS0 uart none
        /sbin/modprobe snd-serial-u16550 port=0x3f8 irq=4 adaptor=3