The ti,no-reset-on-init flag need to be at the interconnect target module
level for the modules that have it defined.
The ti-sysc driver handles this case, but produces warning, not a critical
issue.
Signed-off-by: Grygorii Strashko <grygorii.strashko@ti.com>
Signed-off-by: Tony Lindgren <tony@atomide.com>
>;
};
-&gpio3 {
- status = "okay";
+&gpio3_target {
ti,no-reset-on-init;
};
-&gpio2 {
+&gpio2_target {
status = "okay";
ti,no-reset-on-init;
};
};
};
- target-module@55000 { /* 0x48055000, ap 13 0e.0 */
+ gpio2_target: target-module@55000 { /* 0x48055000, ap 13 0e.0 */
compatible = "ti,sysc-omap2", "ti,sysc";
reg = <0x55000 0x4>,
<0x55010 0x4>,
};
};
- target-module@57000 { /* 0x48057000, ap 15 06.0 */
+ gpio3_target: target-module@57000 { /* 0x48057000, ap 15 06.0 */
compatible = "ti,sysc-omap2", "ti,sysc";
reg = <0x57000 0x4>,
<0x57010 0x4>,