TXIQ and RXIQ share the same data path to upload the measurement
result, we should turn off RXIQ calibration while re-calibrating radio
Signed-off-by: Bala Shanmugam <bkamatch@qca.qualcomm.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
mci_hw->bt_state = MCI_BT_AWAKE;
+ REG_CLR_BIT(ah, AR_PHY_TIMING4,
+ 1 << AR_PHY_TIMING_CONTROL4_DO_GAIN_DC_IQ_CAL_SHIFT);
+
if (caldata) {
caldata->done_txiqcal_once = false;
caldata->done_txclcal_once = false;
if (!ath9k_hw_init_cal(ah, chan))
return -EIO;
+ REG_SET_BIT(ah, AR_PHY_TIMING4,
+ 1 << AR_PHY_TIMING_CONTROL4_DO_GAIN_DC_IQ_CAL_SHIFT);
+
exit:
ar9003_mci_enable_interrupt(ah);
return 0;
#define AR_PHY_SPUR_REG (AR_CHAN_BASE + 0x1c)
#define AR_PHY_RX_IQCAL_CORR_B0 (AR_CHAN_BASE + 0xdc)
#define AR_PHY_TX_IQCAL_CONTROL_3 (AR_CHAN_BASE + 0xb0)
+#define AR_PHY_TIMING_CONTROL4_DO_GAIN_DC_IQ_CAL_SHIFT 16
#define AR_PHY_TIMING11_SPUR_FREQ_SD 0x3FF00000
#define AR_PHY_TIMING11_SPUR_FREQ_SD_S 20