sunxi: clocks: Use the correct pattern register for PLL11
authorPhilipp Tomsich <philipp.tomsich@theobroma-systems.com>
Mon, 2 Jan 2017 11:48:41 +0000 (11:48 +0000)
committerJagan Teki <jagan@openedev.com>
Wed, 4 Jan 2017 15:37:42 +0000 (16:37 +0100)
Signed-off-by: Philipp Tomsich <philipp.tomsich@theobroma-systems.com>
Signed-off-by: Andre Przywara <andre.przywara@arm.com>
Acked-by: Maxime Ripard <maxime.ripard@free-electrons.com>
Reviewed-by: Jagan Teki <jagan@openedev.com>
arch/arm/mach-sunxi/clock_sun6i.c

index 80cfc0b..8e39bbe 100644 (file)
@@ -224,7 +224,7 @@ void clock_set_pll11(unsigned int clk, bool sigma_delta_enable)
                (struct sunxi_ccm_reg *)SUNXI_CCM_BASE;
 
        if (sigma_delta_enable)
-               writel(CCM_PLL11_PATTERN, &ccm->pll5_pattern_cfg);
+               writel(CCM_PLL11_PATTERN, &ccm->pll11_pattern_cfg0);
 
        writel(CCM_PLL11_CTRL_EN | CCM_PLL11_CTRL_UPD |
               (sigma_delta_enable ? CCM_PLL11_CTRL_SIGMA_DELTA_EN : 0) |