Previously the register interface was not attached to any internal bus,
which is not correct - it lives on the APB.
Cc: Stefan M Schaeckeler <sschaeck@cisco.com>
Signed-off-by: Andrew Jeffery <andrew@aj.id.au>
Reviewed-by: Joel Stanley <joel@jms.id.au>
Reviewed-by: Stefan Schaeckeler <sschaeck@cisco.com>
Signed-off-by: Joel Stanley <joel@jms.id.au>
reg = <0x80000000 0>;
};
- edac: sdram@1e6e0000 {
- compatible = "aspeed,ast2500-sdram-edac";
- reg = <0x1e6e0000 0x174>;
- interrupts = <0>;
- status = "disabled";
- };
-
ahb {
compatible = "simple-bus";
#address-cells = <1>;
#size-cells = <1>;
ranges;
+ edac: sdram@1e6e0000 {
+ compatible = "aspeed,ast2500-sdram-edac";
+ reg = <0x1e6e0000 0x174>;
+ interrupts = <0>;
+ status = "disabled";
+ };
+
syscon: syscon@1e6e2000 {
compatible = "aspeed,ast2500-scu", "syscon", "simple-mfd";
reg = <0x1e6e2000 0x1a8>;