Revert "power: remove POWER_SUPPLY_PROP_CAPACITY_LEVEL"
authorAndres Salomon <dilinger@collabora.co.uk>
Tue, 30 Jun 2009 06:13:01 +0000 (02:13 -0400)
committerAnton Vorontsov <cbouatmailru@gmail.com>
Tue, 30 Jun 2009 22:44:03 +0000 (02:44 +0400)
This reverts commit 8efe444038a205e79b38b7ad03878824901849a8 and
4cbc76eadf56399cd11fb736b33c53aec9caab8c.

Richard@laptop.org was apparently using CAPACITY_LEVEL for debugging
battery/EC problems, and was upset that it was removed.  This readds it.

Conflicts:

Documentation/power_supply_class.txt

Signed-off-by: Andres Salomon <dilinger@collabora.co.uk>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
Documentation/power/power_supply_class.txt
drivers/power/olpc_battery.c
drivers/power/power_supply_sysfs.c
include/linux/power_supply.h

index c6cd495..709d955 100644 (file)
@@ -108,6 +108,8 @@ relative, time-based measurements.
 ENERGY_FULL, ENERGY_EMPTY - same as above but for energy.
 
 CAPACITY - capacity in percents.
+CAPACITY_LEVEL - capacity level. This corresponds to
+POWER_SUPPLY_CAPACITY_LEVEL_*.
 
 TEMP - temperature of the power supply.
 TEMP_AMBIENT - ambient temperature.
index 58e4192..3a589df 100644 (file)
@@ -276,6 +276,14 @@ static int olpc_bat_get_property(struct power_supply *psy,
                        return ret;
                val->intval = ec_byte;
                break;
+       case POWER_SUPPLY_PROP_CAPACITY_LEVEL:
+               if (ec_byte & BAT_STAT_FULL)
+                       val->intval = POWER_SUPPLY_CAPACITY_LEVEL_FULL;
+               else if (ec_byte & BAT_STAT_LOW)
+                       val->intval = POWER_SUPPLY_CAPACITY_LEVEL_LOW;
+               else
+                       val->intval = POWER_SUPPLY_CAPACITY_LEVEL_NORMAL;
+               break;
        case POWER_SUPPLY_PROP_TEMP:
                ret = olpc_ec_cmd(EC_BAT_TEMP, NULL, 0, (void *)&ec_word, 2);
                if (ret)
@@ -321,6 +329,7 @@ static enum power_supply_property olpc_bat_props[] = {
        POWER_SUPPLY_PROP_VOLTAGE_AVG,
        POWER_SUPPLY_PROP_CURRENT_AVG,
        POWER_SUPPLY_PROP_CAPACITY,
+       POWER_SUPPLY_PROP_CAPACITY_LEVEL,
        POWER_SUPPLY_PROP_TEMP,
        POWER_SUPPLY_PROP_TEMP_AMBIENT,
        POWER_SUPPLY_PROP_MANUFACTURER,
index da73591..9deabbd 100644 (file)
@@ -51,6 +51,9 @@ static ssize_t power_supply_show_property(struct device *dev,
                "Unknown", "NiMH", "Li-ion", "Li-poly", "LiFe", "NiCd",
                "LiMn"
        };
+       static char *capacity_level_text[] = {
+               "Unknown", "Critical", "Low", "Normal", "High", "Full"
+       };
        ssize_t ret;
        struct power_supply *psy = dev_get_drvdata(dev);
        const ptrdiff_t off = attr - power_supply_attrs;
@@ -71,6 +74,8 @@ static ssize_t power_supply_show_property(struct device *dev,
                return sprintf(buf, "%s\n", health_text[value.intval]);
        else if (off == POWER_SUPPLY_PROP_TECHNOLOGY)
                return sprintf(buf, "%s\n", technology_text[value.intval]);
+       else if (off == POWER_SUPPLY_PROP_CAPACITY_LEVEL)
+               return sprintf(buf, "%s\n", capacity_level_text[value.intval]);
        else if (off >= POWER_SUPPLY_PROP_MODEL_NAME)
                return sprintf(buf, "%s\n", value.strval);
 
@@ -109,6 +114,7 @@ static struct device_attribute power_supply_attrs[] = {
        POWER_SUPPLY_ATTR(energy_now),
        POWER_SUPPLY_ATTR(energy_avg),
        POWER_SUPPLY_ATTR(capacity),
+       POWER_SUPPLY_ATTR(capacity_level),
        POWER_SUPPLY_ATTR(temp),
        POWER_SUPPLY_ATTR(temp_ambient),
        POWER_SUPPLY_ATTR(time_to_empty_now),
index 594c494..0ab6aa1 100644 (file)
@@ -58,6 +58,15 @@ enum {
        POWER_SUPPLY_TECHNOLOGY_LiMn,
 };
 
+enum {
+       POWER_SUPPLY_CAPACITY_LEVEL_UNKNOWN = 0,
+       POWER_SUPPLY_CAPACITY_LEVEL_CRITICAL,
+       POWER_SUPPLY_CAPACITY_LEVEL_LOW,
+       POWER_SUPPLY_CAPACITY_LEVEL_NORMAL,
+       POWER_SUPPLY_CAPACITY_LEVEL_HIGH,
+       POWER_SUPPLY_CAPACITY_LEVEL_FULL,
+};
+
 enum power_supply_property {
        /* Properties of type `int' */
        POWER_SUPPLY_PROP_STATUS = 0,
@@ -89,6 +98,7 @@ enum power_supply_property {
        POWER_SUPPLY_PROP_ENERGY_NOW,
        POWER_SUPPLY_PROP_ENERGY_AVG,
        POWER_SUPPLY_PROP_CAPACITY, /* in percents! */
+       POWER_SUPPLY_PROP_CAPACITY_LEVEL,
        POWER_SUPPLY_PROP_TEMP,
        POWER_SUPPLY_PROP_TEMP_AMBIENT,
        POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW,