scsi: megaraid_sas: Return the DCMD status from megasas_get_seq_num
authorShivasharan S <shivasharan.srikanteshwara@broadcom.com>
Fri, 5 Jan 2018 13:27:38 +0000 (05:27 -0800)
committerMartin K. Petersen <martin.petersen@oracle.com>
Thu, 11 Jan 2018 04:25:14 +0000 (23:25 -0500)
In megasas_get_seq_num, the status of the DCMD fired to FW is not
returned, it always returns success.  We could end up registering AEN
request with incorrect sequence number if the DCMD failed.  Return the
DCMD status back to caller.  This was discovered during code review and
very rare to see issue in field to see AEN request failed bt FW.

Signed-off-by: Shivasharan S <shivasharan.srikanteshwara@broadcom.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
drivers/scsi/megaraid/megaraid_sas_base.c

index ed106cb..3812091 100644 (file)
@@ -5581,6 +5581,7 @@ megasas_get_seq_num(struct megasas_instance *instance,
        struct megasas_dcmd_frame *dcmd;
        struct megasas_evt_log_info *el_info;
        dma_addr_t el_info_h = 0;
+       int ret;
 
        cmd = megasas_get_cmd(instance);
 
@@ -5613,26 +5614,29 @@ megasas_get_seq_num(struct megasas_instance *instance,
        megasas_set_dma_settings(instance, dcmd, el_info_h,
                                 sizeof(struct megasas_evt_log_info));
 
-       if (megasas_issue_blocked_cmd(instance, cmd, MFI_IO_TIMEOUT_SECS) ==
-               DCMD_SUCCESS) {
-               /*
-                * Copy the data back into callers buffer
-                */
-               eli->newest_seq_num = el_info->newest_seq_num;
-               eli->oldest_seq_num = el_info->oldest_seq_num;
-               eli->clear_seq_num = el_info->clear_seq_num;
-               eli->shutdown_seq_num = el_info->shutdown_seq_num;
-               eli->boot_seq_num = el_info->boot_seq_num;
-       } else
-               dev_err(&instance->pdev->dev, "DCMD failed "
-                       "from %s\n", __func__);
+       ret = megasas_issue_blocked_cmd(instance, cmd, MFI_IO_TIMEOUT_SECS);
+       if (ret != DCMD_SUCCESS) {
+               dev_err(&instance->pdev->dev, "Failed from %s %d\n",
+                       __func__, __LINE__);
+               goto dcmd_failed;
+       }
+
+       /*
+        * Copy the data back into callers buffer
+        */
+       eli->newest_seq_num = el_info->newest_seq_num;
+       eli->oldest_seq_num = el_info->oldest_seq_num;
+       eli->clear_seq_num = el_info->clear_seq_num;
+       eli->shutdown_seq_num = el_info->shutdown_seq_num;
+       eli->boot_seq_num = el_info->boot_seq_num;
 
+dcmd_failed:
        pci_free_consistent(instance->pdev, sizeof(struct megasas_evt_log_info),
                            el_info, el_info_h);
 
        megasas_return_cmd(instance, cmd);
 
-       return 0;
+       return ret;
 }
 
 /**