imx: ventana: gw5904/gw5909: disable RS485
authorTim Harvey <tharvey@gateworks.com>
Mon, 4 Feb 2019 21:10:59 +0000 (13:10 -0800)
committerStefano Babic <sbabic@denx.de>
Fri, 15 Feb 2019 21:01:15 +0000 (22:01 +0100)
The GW5904/GW5909 have a SP33E multi-protocol serial transceiver which we
want to configure to RS232 by default (by de-asserting RS485_EN)

Signed-off-by: Tim Harvey <tharvey@gateworks.com>
board/gateworks/gw_ventana/common.c

index 8934f21..8786a12 100644 (file)
@@ -1429,6 +1429,8 @@ void setup_iomux_gpio(int board, struct ventana_board_info *info)
                break;
        case GW5909:
        case GW5904:
+               gpio_request(IMX_GPIO_NR(4, 23), "rs485_en");
+               gpio_direction_output(IMX_GPIO_NR(4, 23), 0);
                gpio_request(IMX_GPIO_NR(5, 11), "skt1_wdis#");
                gpio_direction_output(IMX_GPIO_NR(5, 11), 1);
                gpio_request(IMX_GPIO_NR(5, 12), "skt1_rst#");