The (*do_cmdtest) validates the scan_begin_src as TRIG_FOLLOW, TRIG_TIMER,
or TRIG_EXT. Remove the invalid check for TRIG_INT in the (*do_cmd).
Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com>
Reviewed-by: Ian Abbott <abbotti@mev.co.uk>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
* channel manipulation without timers effect
*/
if (((cmd->scan_begin_src == TRIG_FOLLOW) ||
- (cmd->scan_begin_src == TRIG_EXT) ||
- (cmd->scan_begin_src == TRIG_INT)) &&
+ (cmd->scan_begin_src == TRIG_EXT)) &&
(cmd->convert_src == TRIG_TIMER)) {
/* both timer is used for one time */
if (cmd->scan_begin_src == TRIG_EXT)