In the current code, vendor-specific MADs (e.g with the FDR-10
attribute) are silently dropped by the driver, resulting in timeouts
at the sending side and inability to query/configure the relevant
feature. However, the ConnectX firmware is able to handle such MADs.
For unsupported attributes, the firmware returns a GET_RESPONSE MAD
containing an error status.
For example, for a FDR-10 node with LID 11:
# ibstat mlx4_0 1
CA: 'mlx4_0'
Port 1:
State: Active
Physical state: LinkUp
Rate: 40 (FDR10)
Base lid: 11
LMC: 0
SM lid: 24
Capability mask: 0x02514868
Port GUID: 0x0002c903002e65d1
Link layer: InfiniBand
Extended Port Query (EPI) vendor mad timeouts before the patch:
# smpquery MEPI 11 -d
ibwarn: [4196] smp_query_via: attr 0xff90 mod 0x0 route Lid 11
ibwarn: [4196] _do_madrpc: retry 1 (timeout 1000 ms)
ibwarn: [4196] _do_madrpc: retry 2 (timeout 1000 ms)
ibwarn: [4196] _do_madrpc: timeout after 3 retries, 3000 ms
ibwarn: [4196] mad_rpc: _do_madrpc failed; dport (Lid 11)
smpquery: iberror: [pid 4196] main: failed: operation EPI: ext port info query failed
EPI query works OK with the patch:
# smpquery MEPI 11 -d
ibwarn: [6548] smp_query_via: attr 0xff90 mod 0x0 route Lid 11
ibwarn: [6548] mad_rpc: data offs 64 sz 64
mad data
0000 0000 0000 0001 0000 0001 0000 0001
0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000
# Ext Port info: Lid 11 port 0
StateChangeEnable:...............0x00
LinkSpeedSupported:..............0x01
LinkSpeedEnabled:................0x01
LinkSpeedActive:.................0x01
Signed-off-by: Jack Morgenstein <jackm@mellanox.com>
Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com>
Acked-by: Ira Weiny <weiny2@llnl.gov>
Cc: <stable@vger.kernel.org>
Signed-off-by: Roland Dreier <roland@purestorage.com>
return IB_MAD_RESULT_SUCCESS;
/*
- * Don't process SMInfo queries or vendor-specific
- * MADs -- the SMA can't handle them.
+ * Don't process SMInfo queries -- the SMA can't handle them.
*/
- if (in_mad->mad_hdr.attr_id == IB_SMP_ATTR_SM_INFO ||
- ((in_mad->mad_hdr.attr_id & IB_SMP_ATTR_VENDOR_MASK) ==
- IB_SMP_ATTR_VENDOR_MASK))
+ if (in_mad->mad_hdr.attr_id == IB_SMP_ATTR_SM_INFO)
return IB_MAD_RESULT_SUCCESS;
} else if (in_mad->mad_hdr.mgmt_class == IB_MGMT_CLASS_PERF_MGMT ||
in_mad->mad_hdr.mgmt_class == MLX4_IB_VENDOR_CLASS1 ||