In the original code the parenthesis are in the wrong position, so the
conditions are always true.
Signed-off-by: Dan Carpenter <error27@gmail.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
unsigned char XGI_IsLCDDualLink(struct vb_device_info *pVBInfo)
{
- if ((((pVBInfo->VBInfo & SetCRT2ToLCD) | SetCRT2ToLCDA))
- && (pVBInfo->LCDInfo & SetLCDDualLink)) /* shampoo0129 */
+ if ((pVBInfo->VBInfo & (SetCRT2ToLCD | SetCRT2ToLCDA)) &&
+ (pVBInfo->LCDInfo & SetLCDDualLink)) /* shampoo0129 */
return 1;
return 0;
if (pVBInfo->IF_DEF_LVDS == 0) {
CRT2Index = CRT2Index >> 6; /* for LCD */
- if (((pVBInfo->VBInfo & SetCRT2ToLCD) | SetCRT2ToLCDA)) { /*301b*/
+ if (pVBInfo->VBInfo & (SetCRT2ToLCD | SetCRT2ToLCDA)) { /*301b*/
if (pVBInfo->LCDResInfo != Panel1024x768)
VCLKIndex = LCDXlat2VCLK[CRT2Index];
else