This fixes a bug where, when temperature is outside of the linear range, fan
pwm would be outside of the allowed range ([0, 100]) and could get negative in
some cases.
It seems like a regression that happened when we re-worked the fan management
logic before merging.
Tested-by: Ozan Çağlayan <ozancag@gmail.com>
Signed-off-by: Martin Peres <martin.peres@labri.fr>
Signed-off-by: Ben Skeggs <bskeggs@redhat.com>
u8 temp = therm->temp_get(therm);
u16 duty;
+ /* handle the non-linear part first */
+ if (temp < linear_min_temp)
+ return priv->fan->bios.min_duty;
+ else if (temp > linear_max_temp)
+ return priv->fan->bios.max_duty;
+
+ /* we are in the linear zone */
duty = (temp - linear_min_temp);
duty *= (priv->fan->bios.max_duty - priv->fan->bios.min_duty);
duty /= (linear_max_temp - linear_min_temp);