This adds the operating points to the Ux500 device tree and
deletes the old special-purpose cpufreq node, as we can now
use the generic DT cpufreq driver.
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Arnd Bergmann <arnd@arndb.de>
device_type = "cpu";
compatible = "arm,cortex-a9";
reg = <0x300>;
+ /* cpufreq controls */
+ operating-points = <998400 0
+ 800000 0
+ 400000 0
+ 200000 0>;
+ clocks = <&prcmu_clk PRCMU_ARMSS>;
+ clock-names = "cpu";
+ clock-latency = <20000>;
};
CPU1: cpu@301 {
device_type = "cpu";
reg = <0x80157450 0xC>;
};
- cpufreq {
- compatible = "stericsson,cpufreq-ux500";
- clocks = <&prcmu_clk PRCMU_ARMSS>;
- clock-names = "armss";
- status = "disabled";
- };
-
thermal@801573c0 {
compatible = "stericsson,db8500-thermal";
reg = <0x801573c0 0x40>;