When cfg80211 starts it will send a core regulatory hint. This is
sent to the global workqueue but we force processing of it by
flushing the global workqueue. The flushing was done since
cfg80211 needs last_request to always be populated.
Avoid flushing the global workqueue by processing the work
required immediately instead of putting it into a linked
list and processing it after the flush.
Signed-off-by: Luis R. Rodriguez <lrodriguez@atheros.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
request->alpha2[1] = alpha2[1];
request->initiator = NL80211_REGDOM_SET_BY_CORE;
- queue_regulatory_request(request);
-
/*
* This ensures last_request is populated once modules
* come swinging in and calling regulatory hints and
* wiphy_apply_custom_regulatory().
*/
- flush_scheduled_work();
+ reg_process_hint(request);
return 0;
}