The sh_tmu driver gets the TMU functional clock using a connection ID of
"tmu_fck". While all SH SoCs create clock lookup entries with a NULL
device ID and a "tmu_fck" connection ID, the ARM SoCs use the device ID
only with a NULL connection ID. This works on legacy platforms but will
break on ARM with DT boot.
Fix the situation by using a connection ID of "fck" in the non-legacy
platform data case. Clock lookup entries will be renamed to use the
device ID as well as the connection ID as platforms get moved to new
platform data. The legacy code will eventually be dropped, leaving us
with device ID based clock lookup, compatible with DT boot.
Signed-off-by: Laurent Pinchart <laurent.pinchart+renesas@ideasonboard.com>
(cherry picked from commit
a27d922749f3be0a88f7e0aeb507c373703c08ee)
Signed-off-by: Simon Horman <horms+renesas@verge.net.au>
tmu->model = id->driver_data;
/* Get hold of clock. */
- tmu->clk = clk_get(&tmu->pdev->dev, "tmu_fck");
+ tmu->clk = clk_get(&tmu->pdev->dev,
+ tmu->model == SH_TMU_LEGACY ? "tmu_fck" : "fck");
if (IS_ERR(tmu->clk)) {
dev_err(&tmu->pdev->dev, "cannot get clock\n");
return PTR_ERR(tmu->clk);