xea: spl: Disable pull UP for GPIO0_2{35}
authorLukasz Majewski <lukma@denx.de>
Sat, 26 Dec 2020 00:09:00 +0000 (01:09 +0100)
committerTom Rini <trini@konsulko.com>
Fri, 8 Jan 2021 13:41:50 +0000 (08:41 -0500)
On the imx287 pin GPMI_WRN (GPIO0_25) no PullUP is available that can be
enabled.

To get the same behavior for both boot select pins (i.e. GPIO0_2{35})
disable pull UPs on both.

Signed-off-by: Lukasz Majewski <lukma@denx.de>
board/liebherr/xea/spl_xea.c

index d88b75b..192f68f 100644 (file)
@@ -20,7 +20,7 @@
 #include <asm/arch/sys_proto.h>
 
 #define        MUX_CONFIG_LCD  (MXS_PAD_3V3 | MXS_PAD_4MA | MXS_PAD_NOPULL)
-#define        MUX_CONFIG_BOOT (MXS_PAD_3V3 | MXS_PAD_PULLUP)
+#define        MUX_CONFIG_BOOT (MXS_PAD_3V3)
 #define        MUX_CONFIG_TSC  (MXS_PAD_3V3 | MXS_PAD_8MA | MXS_PAD_PULLUP)
 #define        MUX_CONFIG_SSP0 (MXS_PAD_3V3 | MXS_PAD_12MA | MXS_PAD_PULLUP)
 #define        MUX_CONFIG_SSP2 (MXS_PAD_3V3 | MXS_PAD_4MA | MXS_PAD_PULLUP)