Fix regression caused by commit
507e2fbaaacb6f164b4125b87c5002f95143174b
("w1: w1 temp calculation overflow fix") whereby negative temperatures for
the DS18B20 are not converted properly.
When the temperature exceeds 32767 milli-degrees the temperature overflows
to -32768 millidegrees. These are both well within the -55 - +125 degree
range for the sensor.
Addresses https://bugzilla.kernel.org/show_bug.cgi?id=12646
Signed-of-by: Ian Dall <ian@beware.dropbear.id.au>
Cc: Evgeniy Polyakov <johnpol@2ka.mipt.ru>
Tested-by: Karsten Elfenbein <kelfe@gmx.de>
Cc: <stable@kernel.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
static inline int w1_DS18B20_convert_temp(u8 rom[9])
{
- int t = ((s16)rom[1] << 8) | rom[0];
- t = t*1000/16;
- return t;
+ s16 t = le16_to_cpup((__le16 *)rom);
+ return t*1000/16;
}
static inline int w1_DS18S20_convert_temp(u8 rom[9])