dt-bindings: power: Introduce one property to describe the battery resistance with...
authorBaolin Wang <baolin.wang@linaro.org>
Mon, 9 Dec 2019 03:56:21 +0000 (11:56 +0800)
committerSebastian Reichel <sebastian.reichel@collabora.com>
Thu, 19 Dec 2019 00:36:32 +0000 (01:36 +0100)
Since the battery internal resistance can be changed as the temperature
changes, thus add one table to describe the battery resistance percent
in different temperatures to get a accurate battery internal resistance.

Reviewed-by: Rob Herring <robh@kernel.org>
Signed-off-by: Baolin Wang <baolin.wang@linaro.org>
Signed-off-by: Baolin Wang <baolin.wang7@gmail.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Documentation/devicetree/bindings/power/supply/battery.txt

index 5c913d4..3049cf8 100644 (file)
@@ -35,6 +35,10 @@ Optional Properties:
    for each of the battery capacity lookup table. The first temperature value
    specifies the OCV table 0, and the second temperature value specifies the
    OCV table 1, and so on.
+ - resistance-temp-table: An array providing the temperature in degree Celsius
+   and corresponding battery internal resistance percent, which is used to look
+   up the resistance percent according to current temperature to get a accurate
+   batterty internal resistance in different temperatures.
 
 Battery properties are named, where possible, for the corresponding
 elements in enum power_supply_property, defined in
@@ -61,6 +65,7 @@ Example:
                ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>, ...;
                ocv-capacity-table-1 = <4200000 100>, <4185000 95>, <4113000 90>, ...;
                ocv-capacity-table-2 = <4250000 100>, <4200000 95>, <4185000 90>, ...;
+               resistance-temp-table = <20 100>, <10 90>, <0 80>, <(-10) 60>;
        };
 
        charger: charger@11 {