- interrupts : should contain the IRQ line for this Unicam instance.
- clocks : list of clock specifiers, corresponding to entries in
clock-names property.
-- clock-names : must contain an "lp" entry, matching entries in the
+- clock-names : must contain "lp" and "vpu" entries, matching entries in the
clocks property.
Unicam supports a single port node. It should contain one 'port' child node
reg = <0x7e801000 0x800>,
<0x7e802004 0x4>;
interrupts = <2 7>;
- clocks = <&clocks BCM2835_CLOCK_CAM1>;
- clock-names = "lp";
-
+ clocks = <&clocks BCM2835_CLOCK_CAM1>,
+ <&firmware_clocks 4>;
+ clock-names = "lp", "vpu";
port {
csi1_ep: endpoint {
remote-endpoint = <&tc358743_0>;