net: phy: micrel: make *-skew-ps check more lenient
authorMatthias Schiffer <matthias.schiffer@ew.tq-group.com>
Tue, 12 Oct 2021 10:34:02 +0000 (12:34 +0200)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Thu, 18 Nov 2021 18:16:16 +0000 (19:16 +0100)
[ Upstream commit 67ca5159dbe2edb5dae7544447b8677d2596933a ]

It seems reasonable to fine-tune only some of the skew values when using
one of the rgmii-*id PHY modes, and even when all skew values are
specified, using the correct ID PHY mode makes sense for documentation
purposes. Such a configuration also appears in the binding docs in
Documentation/devicetree/bindings/net/micrel-ksz90x1.txt, so the driver
should not warn about it.

Signed-off-by: Matthias Schiffer <matthias.schiffer@ew.tq-group.com>
Link: https://lore.kernel.org/r/20211012103402.21438-1-matthias.schiffer@ew.tq-group.com
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
Signed-off-by: Sasha Levin <sashal@kernel.org>
drivers/net/phy/micrel.c

index 5c928f8..643b1c1 100644 (file)
@@ -863,9 +863,9 @@ static int ksz9031_config_init(struct phy_device *phydev)
                                MII_KSZ9031RN_TX_DATA_PAD_SKEW, 4,
                                tx_data_skews, 4, &update);
 
-               if (update && phydev->interface != PHY_INTERFACE_MODE_RGMII)
+               if (update && !phy_interface_is_rgmii(phydev))
                        phydev_warn(phydev,
-                                   "*-skew-ps values should be used only with phy-mode = \"rgmii\"\n");
+                                   "*-skew-ps values should be used only with RGMII PHY modes\n");
 
                /* Silicon Errata Sheet (DS80000691D or DS80000692D):
                 * When the device links in the 1000BASE-T slave mode only,