ata: pata_at91.c bugfix for high master clock
authorIgor Plyatov <plyatov@gmail.com>
Mon, 28 Mar 2011 12:56:15 +0000 (16:56 +0400)
committerJeff Garzik <jgarzik@pobox.com>
Sun, 24 Apr 2011 15:34:06 +0000 (11:34 -0400)
The AT91SAM9 microcontrollers with master clock higher then 105 MHz
and PIO0, have overflow of the NCS_RD_PULSE value in the MSB. This
lead to "NCS_RD_PULSE" pulse longer then "NRD_CYCLE" pulse and driver
does not detect ATA device.

Signed-off-by: Igor Plyatov <plyatov@gmail.com>
Signed-off-by: Jeff Garzik <jgarzik@pobox.com>
drivers/ata/pata_at91.c

index 0da0dcc..a9a066a 100644 (file)
 
 
 #define DRV_NAME "pata_at91"
-#define DRV_VERSION "0.1"
+#define DRV_VERSION "0.2"
 
 #define CF_IDE_OFFSET      0x00c00000
 #define CF_ALT_IDE_OFFSET   0x00e00000
 #define CF_IDE_RES_SIZE     0x08
+#define NCS_RD_PULSE_LIMIT  0x3f /* maximal value for pulse bitfields */
 
 struct at91_ide_info {
        unsigned long mode;
@@ -109,6 +110,11 @@ static void set_smc_timing(struct device *dev,
        /* (CS0, CS1, DIR, OE) <= (CFCE1, CFCE2, CFRNW, NCSX) timings */
        ncs_read_setup = 1;
        ncs_read_pulse = read_cycle - 2;
+       if (ncs_read_pulse > NCS_RD_PULSE_LIMIT) {
+               ncs_read_pulse = NCS_RD_PULSE_LIMIT;
+               dev_warn(dev, "ncs_read_pulse limited to maximal value %lu\n",
+                       ncs_read_pulse);
+       }
 
        /* Write timings same as read timings */
        write_cycle = read_cycle;