ARM: mvebu: fix gated clock documentation
authorGregory CLEMENT <gregory.clement@free-electrons.com>
Wed, 25 Sep 2013 11:24:18 +0000 (13:24 +0200)
committerJason Cooper <jason@lakedaemon.net>
Tue, 8 Oct 2013 15:17:56 +0000 (15:17 +0000)
The gated clock documentation referred only to the Orion SoC whereas
it also applied for the Armada 370/XP SoC. This commit updates the
introduction text and also the list of the compatible strings.

Signed-off-by: Gregory CLEMENT <gregory.clement@free-electrons.com>
Signed-off-by: Jason Cooper <jason@lakedaemon.net>
Documentation/devicetree/bindings/clock/mvebu-gated-clock.txt

index cffc93d..fc2910f 100644 (file)
@@ -1,10 +1,10 @@
-* Gated Clock bindings for Marvell Orion SoCs
+* Gated Clock bindings for Marvell EBU SoCs
 
-Marvell Dove and Kirkwood allow some peripheral clocks to be gated to save
-some power. The clock consumer should specify the desired clock by having
-the clock ID in its "clocks" phandle cell. The clock ID is directly mapped to
-the corresponding clock gating control bit in HW to ease manual clock lookup
-in datasheet.
+Marvell Armada 370/XP, Dove and Kirkwood allow some peripheral clocks to be
+gated to save some power. The clock consumer should specify the desired clock
+by having the clock ID in its "clocks" phandle cell. The clock ID is directly
+mapped to the corresponding clock gating control bit in HW to ease manual clock
+lookup in datasheet.
 
 The following is a list of provided IDs for Armada 370:
 ID     Clock   Peripheral
@@ -94,6 +94,8 @@ ID    Clock   Peripheral
 
 Required properties:
 - compatible : shall be one of the following:
+       "marvell,armada-370-gating-clock" - for Armada 370 SoC clock gating
+       "marvell,armada-xp-gating-clock" - for Armada XP SoC clock gating
        "marvell,dove-gating-clock" - for Dove SoC clock gating
        "marvell,kirkwood-gating-clock" - for Kirkwood SoC clock gating
 - reg : shall be the register address of the Clock Gating Control register