net: hns3: Fix for phy not link up problem after resetting
authorYunsheng Lin <linyunsheng@huawei.com>
Fri, 1 Jun 2018 16:52:07 +0000 (17:52 +0100)
committerDavid S. Miller <davem@davemloft.net>
Fri, 1 Jun 2018 18:23:56 +0000 (14:23 -0400)
When resetting, phy_state_machine may be accessing the phy through
firmware if the phy is not stopped or disconnected, which will
cause firemware timeout problem because the firmware is busy
processing the reset request.

This patch fixes it by disabling the phy when resetting.

Fixes: b940aeae0ed6 ("net: hns3: never send command queue message to IMP when reset")
Signed-off-by: Yunsheng Lin <linyunsheng@huawei.com>
Signed-off-by: Peng Li <lipeng321@huawei.com>
Signed-off-by: Salil Mehta <salil.mehta@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_main.c

index fb44b1e..58fef5e 100644 (file)
@@ -3761,9 +3761,6 @@ static int hclge_ae_start(struct hnae3_handle *handle)
        /* reset tqp stats */
        hclge_reset_tqp_stats(handle);
 
-       if (test_bit(HCLGE_STATE_RST_HANDLING, &hdev->state))
-               return 0;
-
        ret = hclge_mac_start_phy(hdev);
        if (ret)
                return ret;
@@ -3781,8 +3778,10 @@ static void hclge_ae_stop(struct hnae3_handle *handle)
        cancel_work_sync(&hdev->service_task);
        clear_bit(HCLGE_STATE_SERVICE_SCHED, &hdev->state);
 
-       if (test_bit(HCLGE_STATE_RST_HANDLING, &hdev->state))
+       if (test_bit(HCLGE_STATE_RST_HANDLING, &hdev->state)) {
+               hclge_mac_stop_phy(hdev);
                return;
+       }
 
        for (i = 0; i < vport->alloc_tqps; i++)
                hclge_tqp_enable(hdev, i, 0, false);