We sometimes observe failures in the test due to too large discrepancy
between the measured and expected ratios. For example:
TEST: ECMP [FAIL]
Too large discrepancy between expected and measured ratios
INFO: Expected ratio 1.00 Measured ratio 1.11
Fix this by allowing an up to 15% deviation between both ratios.
Another possibility is to increase the number of generated flows, but
this will prolong the execution time of the test, which is already quite
high.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
diff=$(echo $weights_ratio - $packets_ratio | bc -l)
diff=${diff#-}
- test "$(echo "$diff / $weights_ratio > 0.1" | bc -l)" -eq 0
+ test "$(echo "$diff / $weights_ratio > 0.15" | bc -l)" -eq 0
check_err $? "Too large discrepancy between expected and measured ratios"
log_test "$desc"