hwmon: (acpi_power_meter) Fix 4.29 MW bug
authorArmin Wolf <W_Armin@gmx.de>
Fri, 24 Nov 2023 18:27:47 +0000 (19:27 +0100)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 13 Dec 2023 17:45:14 +0000 (18:45 +0100)
[ Upstream commit 1fefca6c57fb928d2131ff365270cbf863d89c88 ]

The ACPI specification says:

"If an error occurs while obtaining the meter reading or if the value
is not available then an Integer with all bits set is returned"

Since the "integer" is 32 bits in case of the ACPI power meter,
userspace will get a power reading of 2^32 * 1000 miliwatts (~4.29 MW)
in case of such an error. This was discovered due to a lm_sensors
bugreport (https://github.com/lm-sensors/lm-sensors/issues/460).
Fix this by returning -ENODATA instead.

Tested-by: <urbinek@gmail.com>
Fixes: de584afa5e18 ("hwmon driver for ACPI 4.0 power meters")
Signed-off-by: Armin Wolf <W_Armin@gmx.de>
Link: https://lore.kernel.org/r/20231124182747.13956-1-W_Armin@gmx.de
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Sasha Levin <sashal@kernel.org>
drivers/hwmon/acpi_power_meter.c

index fa28d44..b772c07 100644 (file)
@@ -31,6 +31,7 @@
 #define POWER_METER_CAN_NOTIFY (1 << 3)
 #define POWER_METER_IS_BATTERY (1 << 8)
 #define UNKNOWN_HYSTERESIS     0xFFFFFFFF
+#define UNKNOWN_POWER          0xFFFFFFFF
 
 #define METER_NOTIFY_CONFIG    0x80
 #define METER_NOTIFY_TRIP      0x81
@@ -348,6 +349,9 @@ static ssize_t show_power(struct device *dev,
        update_meter(resource);
        mutex_unlock(&resource->lock);
 
+       if (resource->power == UNKNOWN_POWER)
+               return -ENODATA;
+
        return sprintf(buf, "%llu\n", resource->power * 1000);
 }