This change resolves an issue seen in some configurations where the link
may drop to 100Mb/s even though the link itself supports 1000Mb/s. The
issue was root caused to the fact that we were only trying the link once.
Now instead we will try up to 5 attempts on a faulty cable before
downshifting to 100Mb/s.
Signed-off-by: Alexander Duyck <alexander.h.duyck@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
phy_data |= I82580_CFG_ENABLE_DOWNSHIFT;
ret_val = phy->ops.write_reg(hw, I82580_CFG_REG, phy_data);
- if (ret_val)
- goto out;
-
- /* Set number of link attempts before downshift */
- ret_val = phy->ops.read_reg(hw, I82580_CTRL_REG, &phy_data);
- if (ret_val)
- goto out;
- phy_data &= ~I82580_CTRL_DOWNSHIFT_MASK;
- ret_val = phy->ops.write_reg(hw, I82580_CTRL_REG, phy_data);
out:
return ret_val;