commit
7ee3b7ebcb74714df6d94c8f500f307e1ee5dda5 upstream.
The serial interface can be reset by writing 32 consecutive 1s to the device.
'ret' was initialized correctly but its value was overwritten when
ad7793_check_platform_data() was called. Since a dedicated reset function
is present now, it should be used instead.
Fixes:
2edb769d246e ("iio:ad7793: Add support for the ad7798 and ad7799")
Signed-off-by: Dragos Bogdan <dragos.bogdan@analog.com>
Acked-by: Lars-Peter Clausen <lars@metafoo.de>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
unsigned int vref_mv)
{
struct ad7793_state *st = iio_priv(indio_dev);
- int i, ret = -1;
+ int i, ret;
unsigned long long scale_uv;
u32 id;
return ret;
/* reset the serial interface */
- ret = spi_write(st->sd.spi, (u8 *)&ret, sizeof(ret));
+ ret = ad_sd_reset(&st->sd, 32);
if (ret < 0)
goto out;
usleep_range(500, 2000); /* Wait for at least 500us */