[ Upstream commit
3fc134a07438055fc93ce1bbacf2702ddd09500c ]
Transceiver module temperature sensors are indexed after ASIC and
platform sensors. The current label printing method does not take this
into account and simply prints the index of the transceiver module
sensor.
On new systems that have platform sensors this results in incorrect
(shifted) transceiver module labels being printed:
$ sensors
[...]
front panel 002: +37.0°C (crit = +70.0°C, emerg = +75.0°C)
front panel 003: +47.0°C (crit = +70.0°C, emerg = +75.0°C)
[...]
Fix by taking the sensor count into account. After the fix:
$ sensors
[...]
front panel 001: +37.0°C (crit = +70.0°C, emerg = +75.0°C)
front panel 002: +47.0°C (crit = +70.0°C, emerg = +75.0°C)
[...]
Fixes:
a53779de6a0e ("mlxsw: core: Add QSFP module temperature label attribute to hwmon")
Signed-off-by: Vadim Pasternak <vadimp@nvidia.com>
Reviewed-by: Ido Schimmel <idosch@nvidia.com>
Signed-off-by: Petr Machata <petrm@nvidia.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Signed-off-by: Sasha Levin <sashal@kernel.org>
container_of(attr, struct mlxsw_hwmon_attr, dev_attr);
return sprintf(buf, "front panel %03u\n",
- mlxsw_hwmon_attr->type_index);
+ mlxsw_hwmon_attr->type_index + 1 -
+ mlxsw_hwmon_attr->mlxsw_hwmon_dev->sensor_count);
}
static ssize_t