virtio_console: fix a crash in config_work_handler
authorG. Campana <gcampana@quarkslab.com>
Thu, 19 Jan 2017 21:37:46 +0000 (23:37 +0200)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 5 Jul 2017 12:40:22 +0000 (14:40 +0200)
[ Upstream commit 8379cadf71c3ee8173a1c6fc1ea7762a9638c047 ]

Using control_work instead of config_work as the 3rd argument to
container_of results in an invalid portdev pointer. Indeed, the work
structure is initialized as below:

    INIT_WORK(&portdev->config_work, &config_work_handler);

It leads to a crash when portdev->vdev is dereferenced later. This
bug
is triggered when the guest uses a virtio-console without multiport
feature and receives a config_changed virtio interrupt.

Signed-off-by: G. Campana <gcampana@quarkslab.com>
Reviewed-by: Amit Shah <amit.shah@redhat.com>
Signed-off-by: Michael S. Tsirkin <mst@redhat.com>
Signed-off-by: Sasha Levin <alexander.levin@verizon.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/char/virtio_console.c

index 471a301..8f890c1 100644 (file)
@@ -1870,7 +1870,7 @@ static void config_work_handler(struct work_struct *work)
 {
        struct ports_device *portdev;
 
-       portdev = container_of(work, struct ports_device, control_work);
+       portdev = container_of(work, struct ports_device, config_work);
        if (!use_multiport(portdev)) {
                struct virtio_device *vdev;
                struct port *port;