Add thermal zone for the PMIC thermal sensor. Temperatures are based on
downstream values, except for critical trip point where 140°C is used
instead of 145°C due to limitations without a configured ADC.
Signed-off-by: Matti Lehtimäki <matti.lehtimaki@gmail.com>
Signed-off-by: Bjorn Andersson <andersson@kernel.org>
Link: https://lore.kernel.org/r/20230529221501.43455-3-matti.lehtimaki@gmail.com
#include <dt-bindings/interrupt-controller/irq.h>
#include <dt-bindings/spmi/spmi.h>
+
+/ {
+ thermal-zones {
+ pm8841-thermal {
+ polling-delay-passive = <100>;
+ polling-delay = <0>;
+ thermal-sensors = <&pm8841_temp>;
+
+ trips {
+ trip0 {
+ temperature = <105000>;
+ hysteresis = <2000>;
+ type = "passive";
+ };
+
+ trip1 {
+ temperature = <125000>;
+ hysteresis = <2000>;
+ type = "hot";
+ };
+
+ crit {
+ temperature = <140000>;
+ hysteresis = <2000>;
+ type = "critical";
+ };
+ };
+ };
+ };
+};
+
&spmi_bus {
pm8841_0: pm8841@4 {
#interrupt-cells = <2>;
};
- temp-alarm@2400 {
+ pm8841_temp: temp-alarm@2400 {
compatible = "qcom,spmi-temp-alarm";
reg = <0x2400>;
interrupts = <4 0x24 0 IRQ_TYPE_EDGE_RISING>;