This makes the 8250_of driver happy. There are two more drivers in the
tree that bind to mrvl,mmp-uart compatibles: pxa and 8250_pxa and
neither of them requires the reg-shift property, assuming it's always 2.
Signed-off-by: Lubomir Rintel <lkundrak@v3.sk>
Acked-by: Pavel Machek <pavel@ucw.cz>
interrupts = <27>;
clocks = <&soc_clocks MMP2_CLK_UART0>;
resets = <&soc_clocks MMP2_CLK_UART0>;
+ reg-shift = <2>;
status = "disabled";
};
interrupts = <28>;
clocks = <&soc_clocks MMP2_CLK_UART1>;
resets = <&soc_clocks MMP2_CLK_UART1>;
+ reg-shift = <2>;
status = "disabled";
};
interrupts = <24>;
clocks = <&soc_clocks MMP2_CLK_UART2>;
resets = <&soc_clocks MMP2_CLK_UART2>;
+ reg-shift = <2>;
status = "disabled";
};
interrupts = <46>;
clocks = <&soc_clocks MMP2_CLK_UART3>;
resets = <&soc_clocks MMP2_CLK_UART3>;
+ reg-shift = <2>;
status = "disabled";
};