In the AER or firmware reset flow, if we are in fatal error state or
if pci_channel_offline() is true, we don't send any commands to the
firmware because the commands will likely not reach the firmware and
most commands don't matter much because the firmware is likely to be
reset imminently.
However, the HWRM_FUNC_RESET command is different and we should always
attempt to send it. In the AER flow for example, the .slot_reset()
call will trigger this fw command and we need to try to send it to
effect the proper reset.
Fixes: b340dc680ed4 ("bnxt_en: Avoid sending firmware messages when AER error is detected.")
Reviewed-by: Edwin Peer <edwin.peer@broadcom.com>
Signed-off-by: Vasundhara Volam <vasundhara-v.volam@broadcom.com>
Signed-off-by: Michael Chan <michael.chan@broadcom.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
u32 bar_offset = BNXT_GRCPF_REG_CHIMP_COMM;
u16 dst = BNXT_HWRM_CHNL_CHIMP;
- if (BNXT_NO_FW_ACCESS(bp))
+ if (BNXT_NO_FW_ACCESS(bp) &&
+ le16_to_cpu(req->req_type) != HWRM_FUNC_RESET)
return -EBUSY;
if (msg_len > BNXT_HWRM_MAX_REQ_LEN) {