Info values in the 0x00xx range are defined in the CAPI standard
as "Informational, message processed successfully". Therefore a
CONNECT_B3_CONF message with an Info value in that range should
open an NCCI just as with Info==0.
Impact: minor bugfix
Signed-off-by: Tilman Schmidt <tilman@imap.cc>
Acked-by: Karsten Keil <keil@b1-systems.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
if (CAPIMSG_CMD(skb->data) == CAPI_CONNECT_B3_CONF) {
u16 info = CAPIMSG_U16(skb->data, 12); // Info field
- if (info == 0) {
+ if ((info & 0xff00) == 0) {
mutex_lock(&cdev->ncci_list_mtx);
capincci_alloc(cdev, CAPIMSG_NCCI(skb->data));
mutex_unlock(&cdev->ncci_list_mtx);