pwm: Document that the pinstate of a disabled PWM isn't reliable
authorUwe Kleine-König <u.kleine-koenig@pengutronix.de>
Tue, 17 May 2022 15:05:55 +0000 (17:05 +0200)
committerThierry Reding <thierry.reding@gmail.com>
Fri, 20 May 2022 14:36:07 +0000 (16:36 +0200)
Some (most?) drivers emit the inactive state when the PWM is disabled.
However there are exceptions, so document that a consumer better doesn't
depend on this behaviour.

Some known exceptions:

  - imx27 emits 0 independent of the configured polarity
  - mxs just drives the output to the last emitted state.
  - iqs620a makes the output tristated on disable, so an external
    pull-down would be required.

Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Acked-by: Alexander Stein <alexander.stein@ew.tq-group.com>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
Documentation/driver-api/pwm.rst

index ccb06e4..fd26c3d 100644 (file)
@@ -49,6 +49,12 @@ After being requested, a PWM has to be configured using::
 
 This API controls both the PWM period/duty_cycle config and the
 enable/disable state.
+
+As a consumer, don't rely on the output's state for a disabled PWM. If it's
+easily possible, drivers are supposed to emit the inactive state, but some
+drivers cannot. If you rely on getting the inactive state, use .duty_cycle=0,
+.enabled=true.
+
 There is also a usage_power setting: If set, the PWM driver is only required to
 maintain the power output but has more freedom regarding signal form.
 If supported by the driver, the signal can be optimized, for example to improve