Juno platforms have a programmable replicator splitting the trace output
to TPIU and ETR. Currently this is not being programmed as it is being
treated as a none-programmable replicator - which is the default
operational mode for these devices. The TPIU in the system is enabled by
default, and this combination is causing back-pressure in the trace
system resulting in overflows at the source.
Replaces the existing definition with one that defines the programmable
replicator, using the "qcom,coresight-replicator1x" driver that provides
the correct functionality for CoreSight programmable replicators.
Reviewed-and-Tested-by: Mathieu Poirier <mathieu.poirier@linaro.org>
Signed-off-by: Mike Leach <mike.leach@linaro.org>
Signed-off-by: Sudeep Holla <sudeep.holla@arm.com>
};
};
- coresight-replicator {
- /*
- * Non-configurable replicators don't show up on the
- * AMBA bus. As such no need to add "arm,primecell".
- */
- compatible = "arm,coresight-replicator";
+ replicator@20120000 {
+ compatible = "qcom,coresight-replicator1x", "arm,primecell";
+ reg = <0 0x20120000 0 0x1000>;
+
+ clocks = <&soc_smc50mhz>;
+ clock-names = "apb_pclk";
+ power-domains = <&scpi_devpd 0>;
ports {
#address-cells = <1>;