KernelVersion:
Contact: linux-iio@vger.kernel.org
Description:
- Reading gives the state of AC excitation.
- Writing '1' enables AC excitation.
+ This attribute, if available, is used to enable the AC
+ excitation mode found on some converters. In ac excitation mode,
+ the polarity of the excitation voltage is reversed on
+ alternate cycles, to eliminate DC errors.
What: /sys/bus/iio/devices/iio:deviceX/bridge_switch_en
KernelVersion:
Contact: linux-iio@vger.kernel.org
Description:
- This bridge switch is used to disconnect it when there is a
- need to minimize the system current consumption.
- Reading gives the state of the bridge switch.
- Writing '1' enables the bridge switch.
+ This attribute, if available, is used to close or open the
+ bridge power down switch found on some converters.
+ In bridge applications, such as strain gauges and load cells,
+ the bridge itself consumes the majority of the current in the
+ system. To minimize the current consumption of the system,
+ the bridge can be disconnected (when it is not being used
+ using the bridge_switch_en attribute.
What: /sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration
KernelVersion:
Initiates the system calibration procedure. This is done on a
single channel at a time. Write '1' to start the calibration.
+What: /sys/bus/iio/devices/iio:deviceX/in_voltage2-voltage2_shorted_raw
+KernelVersion:
+Contact: linux-iio@vger.kernel.org
+Description:
+ Measure voltage from AIN2 pin connected to AIN(+)
+ and AIN(-) shorted.
+
What: /sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration_mode_available
KernelVersion:
Contact: linux-iio@vger.kernel.org
+++ /dev/null
-What: /sys/.../iio:deviceX/ac_excitation_en
-KernelVersion: 3.1.0
-Contact: linux-iio@vger.kernel.org
-Description:
- This attribute, if available, is used to enable the AC
- excitation mode found on some converters. In ac excitation mode,
- the polarity of the excitation voltage is reversed on
- alternate cycles, to eliminate DC errors.
-
-What: /sys/.../iio:deviceX/bridge_switch_en
-KernelVersion: 3.1.0
-Contact: linux-iio@vger.kernel.org
-Description:
- This attribute, if available, is used to close or open the
- bridge power down switch found on some converters.
- In bridge applications, such as strain gauges and load cells,
- the bridge itself consumes the majority of the current in the
- system. To minimize the current consumption of the system,
- the bridge can be disconnected (when it is not being used
- using the bridge_switch_en attribute.