arm64: dts: qcom: pmr735a: stop depending on thermal_zones label
authorDmitry Baryshkov <dmitry.baryshkov@linaro.org>
Sat, 26 Feb 2022 20:50:33 +0000 (23:50 +0300)
committerBjorn Andersson <bjorn.andersson@linaro.org>
Tue, 12 Apr 2022 14:21:17 +0000 (09:21 -0500)
Most of SoC device trees do not provide the thermal_zones label. Thus
stop depending on it and use the full path to the thermal zones nodes.

Fixes: 7a3544e5d4e8 ("arm64: dts: qcom: pmr735a: Add temp-alarm support")
Signed-off-by: Dmitry Baryshkov <dmitry.baryshkov@linaro.org>
Signed-off-by: Bjorn Andersson <bjorn.andersson@linaro.org>
Link: https://lore.kernel.org/r/20220226205035.1826360-6-dmitry.baryshkov@linaro.org
arch/arm64/boot/dts/qcom/pmr735a.dtsi

index b4b6ba2..febda50 100644 (file)
        };
 };
 
-&thermal_zones {
-       pmr735a_thermal: pmr735a-thermal {
-               polling-delay-passive = <100>;
-               polling-delay = <0>;
-               thermal-sensors = <&pmr735a_temp_alarm>;
+/ {
+       thermal-zones {
+               pmr735a_thermal: pmr735a-thermal {
+                       polling-delay-passive = <100>;
+                       polling-delay = <0>;
+                       thermal-sensors = <&pmr735a_temp_alarm>;
 
-               trips {
-                       pmr735a_trip0: trip0 {
-                               temperature = <95000>;
-                               hysteresis = <0>;
-                               type = "passive";
-                       };
+                       trips {
+                               pmr735a_trip0: trip0 {
+                                       temperature = <95000>;
+                                       hysteresis = <0>;
+                                       type = "passive";
+                               };
 
-                       pmr735a_crit: pmr735a-crit {
-                               temperature = <115000>;
-                               hysteresis = <0>;
-                               type = "critical";
+                               pmr735a_crit: pmr735a-crit {
+                                       temperature = <115000>;
+                                       hysteresis = <0>;
+                                       type = "critical";
+                               };
                        };
                };
        };