host->cmd = cmd;
host->cmd_rsp = resp;
- init_completion(&host->cmd_done);
+ // The completion should have been consumed by the previous command
+ // response handler, because the mmc requests should be serialized
+ if (completion_done(&host->cmd_done))
+ dev_err(mmc_dev(host->mmc),
+ "previous command was not handled\n");
sdr_set_bits(host->base + MSDC_INTEN, wints);
sdc_send_cmd(rawcmd, cmd->arg);
MSDC_INT_ACMD19_DONE;
BUG_ON(in_interrupt());
- //init_completion(&host->cmd_done);
//sdr_set_bits(host->base + MSDC_INTEN, wints);
spin_unlock(&host->lock);
//msdc_clr_fifo(host); /* no need */
msdc_dma_on(); /* enable DMA mode first!! */
- init_completion(&host->xfer_done);
+
+ // The completion should have been consumed by the previous
+ // xfer response handler, because the mmc requests should be
+ // serialized
+ if (completion_done(&host->cmd_done))
+ dev_err(mmc_dev(host->mmc),
+ "previous transfer was not handled\n");
/* start the command first*/
if (msdc_command_start(host, cmd, CMD_TIMEOUT) != 0)
/* for read, the data coming too fast, then CRC error
* start DMA no business with CRC.
*/
- //init_completion(&host->xfer_done);
msdc_dma_start(host);
spin_unlock(&host->lock);
}
msdc_init_gpd_bd(host, &host->dma);
+ init_completion(&host->cmd_done);
+ init_completion(&host->xfer_done);
INIT_DELAYED_WORK(&host->card_delaywork, msdc_tasklet_card);
spin_lock_init(&host->lock);
msdc_init_hw(host);