drm/amd/pp: Add cases for getting phys and disp clks for SMU10
authorMikita Lipski <mikita.lipski@amd.com>
Mon, 28 May 2018 15:22:17 +0000 (11:22 -0400)
committerAlex Deucher <alexander.deucher@amd.com>
Tue, 29 May 2018 18:17:10 +0000 (13:17 -0500)
Add case options to retrieve either physical or display clocks with
voltage from SMU controller that are needed by display driver.

Signed-off-by: Mikita Lipski <mikita.lipski@amd.com>
Acked-by: Alex Deucher <alexander.deucher@amd.com>
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
drivers/gpu/drm/amd/powerplay/hwmgr/smu10_hwmgr.c

index 85f84f4..e160b05 100644 (file)
@@ -1000,6 +1000,12 @@ static int smu10_get_clock_by_type_with_voltage(struct pp_hwmgr *hwmgr,
        case amd_pp_soc_clock:
                pclk_vol_table = pinfo->vdd_dep_on_socclk;
                break;
+       case amd_pp_disp_clock:
+               pclk_vol_table = pinfo->vdd_dep_on_dispclk;
+               break;
+       case amd_pp_phy_clock:
+               pclk_vol_table = pinfo->vdd_dep_on_phyclk;
+               break;
        default:
                return -EINVAL;
        }