thermal: rename notify_thermal_framework to thermal_notify_framework
authorEduardo Valentin <eduardo.valentin@ti.com>
Tue, 23 Apr 2013 21:48:14 +0000 (21:48 +0000)
committerZhang Rui <rui.zhang@intel.com>
Wed, 24 Apr 2013 16:56:16 +0000 (00:56 +0800)
To follow the prefix names used by the thermal functions,
this patch renames notify_thermal_framework to thermal_notify_framework.

Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Documentation/thermal/sysfs-api.txt
drivers/thermal/thermal_core.c
include/linux/thermal.h

index b2ffe98..bb42266 100644 (file)
@@ -367,7 +367,7 @@ This function returns the thermal_instance corresponding to a given
 {thermal_zone, cooling_device, trip_point} combination. Returns NULL
 if such an instance does not exist.
 
-5.3:notify_thermal_framework:
+5.3:thermal_notify_framework:
 This function handles the trip events from sensor drivers. It starts
 throttling the cooling devices according to the policy configured.
 For CRITICAL and HOT trip points, this notifies the respective drivers,
index a579c62..fb22ae5 100644 (file)
@@ -1432,7 +1432,7 @@ void thermal_cdev_update(struct thermal_cooling_device *cdev)
 EXPORT_SYMBOL(thermal_cdev_update);
 
 /**
- * notify_thermal_framework - Sensor drivers use this API to notify framework
+ * thermal_notify_framework - Sensor drivers use this API to notify framework
  * @tz:                thermal zone device
  * @trip:      indicates which trip point has been crossed
  *
@@ -1443,11 +1443,11 @@ EXPORT_SYMBOL(thermal_cdev_update);
  * The throttling policy is based on the configured platform data; if no
  * platform data is provided, this uses the step_wise throttling policy.
  */
-void notify_thermal_framework(struct thermal_zone_device *tz, int trip)
+void thermal_notify_framework(struct thermal_zone_device *tz, int trip)
 {
        handle_thermal_trip(tz, trip);
 }
-EXPORT_SYMBOL(notify_thermal_framework);
+EXPORT_SYMBOL(thermal_notify_framework);
 
 /**
  * create_trip_attrs - create attributes for trip points
index ec2b886..d7272ab 100644 (file)
@@ -246,7 +246,7 @@ int get_tz_trend(struct thermal_zone_device *, int);
 struct thermal_instance *get_thermal_instance(struct thermal_zone_device *,
                struct thermal_cooling_device *, int);
 void thermal_cdev_update(struct thermal_cooling_device *);
-void notify_thermal_framework(struct thermal_zone_device *, int);
+void thermal_notify_framework(struct thermal_zone_device *, int);
 
 #ifdef CONFIG_NET
 extern int thermal_generate_netlink_event(struct thermal_zone_device *tz,