[SCSI] mpt2sas: Corrected time stamp
authorKashyap, Desai <kashyap.desai@lsi.com>
Wed, 17 Mar 2010 10:51:33 +0000 (16:21 +0530)
committerJames Bottomley <James.Bottomley@suse.de>
Sun, 11 Apr 2010 14:23:54 +0000 (09:23 -0500)
incorrect timestamp on 32 bit platforms: The upper 32 bit of
the timestamp was getting truncated when converting seconds to
milliseconds, which was due to the variable being long. To fix the problem,
the variable needs to be u64. Also the microseconds conversion to
milliseconds was incorrect; it should be divide by 1000 instead of divide by
8.

Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
drivers/scsi/mpt2sas/mpt2sas_base.c

index fb886d0..2e6e45a 100644 (file)
@@ -3009,8 +3009,8 @@ _base_send_ioc_init(struct MPT2SAS_ADAPTER *ioc, int sleep_flag)
         * since epoch ~ midnight January 1, 1970.
         */
        do_gettimeofday(&current_time);
-       mpi_request.TimeStamp = (current_time.tv_sec * 1000) +
-           (current_time.tv_usec >> 3);
+       mpi_request.TimeStamp = cpu_to_le64((u64)current_time.tv_sec * 1000 +
+           (current_time.tv_usec / 1000));
 
        if (ioc->logging_level & MPT_DEBUG_INIT) {
                u32 *mfp;