While performing cleanup, driver is messing with card->ocr
value by not masking rocr against ocr_avail. Below panic
is observed with some of the SDIO host controllers due to
this. Issue is resolved by reverting incorrect modifications
to vdd.
[ 927.423821] mmc1: Invalid vdd 0x1f
[ 927.423925] Modules linked in: rsi_sdio(+) cmac bnep arc4 rsi_91x
mac80211 cfg80211 btrsi rfcomm bluetooth ecdh_generic
[ 927.424073] CPU: 0 PID: 1624 Comm: insmod Tainted: G W 4.15.0-1000-caracalla #1
[ 927.424075] Hardware name: Dell Inc. Edge Gateway 3003/ , BIOS 01.00.06 01/22/2018
[ 927.424082] RIP: 0010:sdhci_set_power_noreg+0xdd/0x190[sdhci]
[ 927.424085] RSP: 0018:
ffffac3fc064b930 EFLAGS:
00010282
[ 927.424107] Call Trace:
[ 927.424118] sdhci_set_power+0x5a/0x60 [sdhci]
[ 927.424125] sdhci_set_ios+0x360/0x3b0 [sdhci]
[ 927.424133] mmc_set_initial_state+0x92/0x120
[ 927.424137] mmc_power_up.part.34+0x33/0x1d0
[ 927.424141] mmc_power_up+0x17/0x20
[ 927.424147] mmc_sdio_runtime_resume+0x2d/0x50
[ 927.424151] mmc_runtime_resume+0x17/0x20
[ 927.424156] __rpm_callback+0xc4/0x200
[ 927.424161] ? idr_alloc_cyclic+0x57/0xd0
[ 927.424165] ? mmc_runtime_suspend+0x20/0x20
[ 927.424169] rpm_callback+0x24/0x80
[ 927.424172] ? mmc_runtime_suspend+0x20/0x20
[ 927.424176] rpm_resume+0x4b3/0x6c0
[ 927.424181] __pm_runtime_resume+0x4e/0x80
[ 927.424188] driver_probe_device+0x41/0x490
[ 927.424192] __driver_attach+0xdf/0xf0
[ 927.424196] ? driver_probe_device+0x490/0x490
[ 927.424201] bus_for_each_dev+0x6c/0xc0
[ 927.424205] driver_attach+0x1e/0x20
[ 927.424209] bus_add_driver+0x1f4/0x270
[ 927.424217] ? rsi_sdio_ack_intr+0x50/0x50 [rsi_sdio]
[ 927.424221] driver_register+0x60/0xe0
[ 927.424227] ? rsi_sdio_ack_intr+0x50/0x50 [rsi_sdio]
[ 927.424231] sdio_register_driver+0x20/0x30
[ 927.424237] rsi_module_init+0x16/0x40 [rsi_sdio]
Signed-off-by: Siva Rebbagondla <siva.rebbagondla@redpinesignals.com>
Signed-off-by: Amitkumar Karwar <amit.karwar@redpinesignals.com>