- * The LAN8710/LAN8720 requires a minimum of 2 link pulses within 64ms of each
- * other in order to set the ENERGYON bit and exit EDPD mode. If a link partner
- * does send the pulses within this interval, the PHY will remained powered
- * down.
- *
- * This workaround will manually toggle the PHY on/off upon calls to read_status
- * in order to generate link test pulses if the link is down. If a link partner
- * is present, it will respond to the pulses, which will cause the ENERGYON bit
- * to be set and will cause the EDPD mode to be exited.
+ * The LAN87xx suffers from rare absence of the ENERGYON-bit when Ethernet cable
+ * plugs in while LAN87xx is in Energy Detect Power-Down mode. This leads to
+ * unstable detection of plugging in Ethernet cable.
+ * This workaround disables Energy Detect Power-Down mode and waiting for
+ * response on link pulses to detect presence of plugged Ethernet cable.
+ * The Energy Detect Power-Down mode is enabled again in the end of procedure to
+ * save approximately 220 mW of power if cable is unplugged.
*/
static int lan87xx_read_status(struct phy_device *phydev)
{
int err = genphy_read_status(phydev);
+ int i;
if (!phydev->link) {
/* Disable EDPD to wake up PHY */
if (rc < 0)
return rc;
- /* Sleep 64 ms to allow ~5 link test pulses to be sent */
- msleep(64);
+ /* Wait max 640 ms to detect energy */
+ for (i = 0; i < 64; i++) {
+ /* Sleep to allow link test pulses to be sent */
+ msleep(10);
+ rc = phy_read(phydev, MII_LAN83C185_CTRL_STATUS);
+ if (rc < 0)
+ return rc;
+ if (rc & MII_LAN83C185_ENERGYON)
+ break;
+ };
/* Re-enable EDPD */
rc = phy_read(phydev, MII_LAN83C185_CTRL_STATUS);
/* basic functions */
.config_aneg = genphy_config_aneg,
- .read_status = genphy_read_status,
+ .read_status = lan87xx_read_status,
.config_init = smsc_phy_config_init,
.soft_reset = smsc_phy_reset,