Fix Marvell 88e1145 PHY init code
authorAndy Fleming <afleming@freescale.com>
Tue, 8 May 2007 22:23:02 +0000 (17:23 -0500)
committerAndrew Fleming-AFLEMING <afleming@freescale.com>
Wed, 11 Jul 2007 22:52:50 +0000 (17:52 -0500)
Fix a bug in the Marvell 88e1145 PHY init code in the TSEC driver
where the reset was being done after the errata code instead of
before.

Signed-off-by: Haiying Wang <haiying.wang@freescale.com>
Signed-off-by: Andy Fleming <afleming@freescale.com>
drivers/tsec.c

index 1298478..c19d87f 100644 (file)
@@ -1037,14 +1037,16 @@ static struct phy_info phy_info_M88E1145 = {
        "Marvell 88E1145",
        4,
        (struct phy_cmd[]){     /* config */
+                          /* Reset the PHY */
+                          {MIIM_CONTROL, MIIM_CONTROL_RESET, NULL},
+
                           /* Errata E0, E1 */
                           {29, 0x001b, NULL},
                           {30, 0x418f, NULL},
                           {29, 0x0016, NULL},
                           {30, 0xa2da, NULL},
 
-                          /* Reset and configure the PHY */
-                          {MIIM_CONTROL, MIIM_CONTROL_RESET, NULL},
+                          /* Configure the PHY */
                           {MIIM_GBIT_CONTROL, MIIM_GBIT_CONTROL_INIT, NULL},
                           {MIIM_ANAR, MIIM_ANAR_INIT, NULL},
                           {MIIM_88E1011_PHY_SCR, MIIM_88E1011_PHY_MDI_X_AUTO,