Removing dead APM
authorChristoph Egger <siccegge@cs.fau.de>
Mon, 5 Jul 2010 13:31:55 +0000 (16:31 +0300)
committerTony Lindgren <tony@atomide.com>
Mon, 5 Jul 2010 14:03:59 +0000 (17:03 +0300)
APM doesn't exist in Kconfig, therefore removing all references for it
from the source code.

Signed-off-by: Christoph Egger <siccegge@cs.fau.de>
Signed-off-by: Tony Lindgren <tony@atomide.com>
arch/arm/mach-omap1/board-palmte.c

index 51d5c4d..514564f 100644 (file)
@@ -213,90 +213,6 @@ static struct omap_lcd_config palmte_lcd_config __initdata = {
        .ctrl_name      = "internal",
 };
 
-#ifdef CONFIG_APM
-/*
- * Values measured in 10 minute intervals averaged over 10 samples.
- * May differ slightly from device to device but should be accurate
- * enough to give basic idea of battery life left and trigger
- * potential alerts.
- */
-static const int palmte_battery_sample[] = {
-       2194, 2157, 2138, 2120,
-       2104, 2089, 2075, 2061,
-       2048, 2038, 2026, 2016,
-       2008, 1998, 1989, 1980,
-       1970, 1958, 1945, 1928,
-       1910, 1888, 1860, 1827,
-       1791, 1751, 1709, 1656,
-};
-
-#define INTERVAL               10
-#define BATTERY_HIGH_TRESHOLD  66
-#define BATTERY_LOW_TRESHOLD   33
-
-static void palmte_get_power_status(struct apm_power_info *info, int *battery)
-{
-       int charging, batt, hi, lo, mid;
-
-       charging = !gpio_get_value(PALMTE_DC_GPIO);
-       batt = battery[0];
-       if (charging)
-               batt -= 60;
-
-       hi = ARRAY_SIZE(palmte_battery_sample);
-       lo = 0;
-
-       info->battery_flag = 0;
-       info->units = APM_UNITS_MINS;
-
-       if (batt > palmte_battery_sample[lo]) {
-               info->battery_life = 100;
-               info->time = INTERVAL * ARRAY_SIZE(palmte_battery_sample);
-       } else if (batt <= palmte_battery_sample[hi - 1]) {
-               info->battery_life = 0;
-               info->time = 0;
-       } else {
-               while (hi > lo + 1) {
-                       mid = (hi + lo) >> 1;
-                       if (batt <= palmte_battery_sample[mid])
-                               lo = mid;
-                       else
-                               hi = mid;
-               }
-
-               mid = palmte_battery_sample[lo] - palmte_battery_sample[hi];
-               hi = palmte_battery_sample[lo] - batt;
-               info->battery_life = 100 - (100 * lo + 100 * hi / mid) /
-                       ARRAY_SIZE(palmte_battery_sample);
-               info->time = INTERVAL * (ARRAY_SIZE(palmte_battery_sample) -
-                               lo) - INTERVAL * hi / mid;
-       }
-
-       if (charging) {
-               info->ac_line_status = APM_AC_ONLINE;
-               info->battery_status = APM_BATTERY_STATUS_CHARGING;
-               info->battery_flag |= APM_BATTERY_FLAG_CHARGING;
-       } else {
-               info->ac_line_status = APM_AC_OFFLINE;
-               if (info->battery_life > BATTERY_HIGH_TRESHOLD)
-                       info->battery_status = APM_BATTERY_STATUS_HIGH;
-               else if (info->battery_life > BATTERY_LOW_TRESHOLD)
-                       info->battery_status = APM_BATTERY_STATUS_LOW;
-               else
-                       info->battery_status = APM_BATTERY_STATUS_CRITICAL;
-       }
-
-       if (info->battery_life > BATTERY_HIGH_TRESHOLD)
-               info->battery_flag |= APM_BATTERY_FLAG_HIGH;
-       else if (info->battery_life > BATTERY_LOW_TRESHOLD)
-               info->battery_flag |= APM_BATTERY_FLAG_LOW;
-       else
-               info->battery_flag |= APM_BATTERY_FLAG_CRITICAL;
-}
-#else
-#define palmte_get_power_status        NULL
-#endif
-
 static struct omap_board_config_kernel palmte_config[] __initdata = {
        { OMAP_TAG_LCD,         &palmte_lcd_config },
 };