4 Add TX Power field to Adv_Data
5 Add Appearance field to Scan_Rsp
6 Add Local Name in Scan_Rsp
+ 7 Secondary Channel with LE 1M
+ 8 Secondary Channel with LE 2M
+ 9 Secondary Channel with LE Coded
The Flags bit 0 indicates support for connectable advertising
and for switching to connectable advertising independent of the
space is limited a short version or no name information. The
Local Name will be added at the end of the scan response data.
+ The Flags bit 7 indicates support for advertising in secondary
+ channel in LE 1M PHY.
+
+ The Flags bit 8 indicates support for advertising in secondary
+ channel in LE 2M PHY. Primary channel would be on 1M.
+
+ The Flags bit 9 indicates support for advertising in secondary
+ channel in LE CODED PHY.
+
The valid range for Instance identifiers is 1-254. The value 0
is reserved for internal use and the value 255 is reserved for
future extensions. However the Max_Instances value for indicating
4 Add TX Power field to Adv_Data
5 Add Appearance field to Scan_Rsp
6 Add Local Name in Scan_Rsp
+ 7 Secondary Channel with LE 1M
+ 8 Secondary Channel with LE 2M
+ 9 Secondary Channel with LE Coded
When the connectable flag is set, then the controller will use
undirected connectable advertising. The value of the connectable
supported to provide less air traffic for devices implementing
broadcaster role.
+ Secondary channel flags can be used to advertise in secondary
+ channel with the corresponding PHYs. These flag bits are mutually
+ exclusive and setting multiple will result in Invalid Parameter
+ error. Choosing either LE 1M or LE 2M will result in using
+ extended advertising on the primary channel with LE 1M and the
+ respectively LE 1M or LE 2M on the secondary channel. Choosing
+ LE Coded will result in using extended advertising on the primary
+ and secondary channels with LE Coded. Choosing none of these flags
+ will result in legacy advertising.
+
The Duration parameter configures the length of an Instance. The
value is in seconds.