x86: HPET: read back compare register before reading counter
authorThomas Gleixner <tglx@linutronix.de>
Sat, 6 Sep 2008 01:06:08 +0000 (03:06 +0200)
committerThomas Gleixner <tglx@linutronix.de>
Sat, 6 Sep 2008 05:21:17 +0000 (07:21 +0200)
After fixing the u32 thinko I sill had occasional hickups on ATI chipsets
with small deltas. There seems to be a delay between writing the compare
register and the transffer to the internal register which triggers the
interrupt. Reading back the value makes sure, that it hit the internal
match register befor we compare against the counter value.

Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
arch/x86/kernel/hpet.c

index 801497a..73deaff 100644 (file)
@@ -278,6 +278,13 @@ static int hpet_legacy_next_event(unsigned long delta,
        cnt += (u32) delta;
        hpet_writel(cnt, HPET_T0_CMP);
 
+       /*
+        * We need to read back the CMP register to make sure that
+        * what we wrote hit the chip before we compare it to the
+        * counter.
+        */
+       WARN_ON((u32)hpet_readl(HPET_T0_CMP) != cnt);
+
        return (s32)((u32)hpet_readl(HPET_COUNTER) - cnt) >= 0 ? -ETIME : 0;
 }