staging: wilc1000: fix missing read_write setting when reading data
authorColin Ian King <colin.king@canonical.com>
Wed, 19 Dec 2018 16:30:07 +0000 (16:30 +0000)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 9 Jan 2019 16:38:40 +0000 (17:38 +0100)
commit c58eef061dda7d843dcc0ad6fea7e597d4c377c0 upstream.

Currently the cmd.read_write setting is not initialized so it contains
garbage from the stack.  Fix this by setting it to 0 to indicate a
read is required.

Detected by CoverityScan, CID#1357925 ("Uninitialized scalar variable")

Fixes: c5c77ba18ea6 ("staging: wilc1000: Add SDIO/SPI 802.11 driver")
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Cc: stable <stable@vger.kernel.org>
Acked-by: Ajay Singh <ajay.kathat@microchip.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/staging/wilc1000/wilc_sdio.c

index b2080d8..e52c3bd 100644 (file)
@@ -831,6 +831,7 @@ static int sdio_read_int(struct wilc *wilc, u32 *int_status)
        if (!g_sdio.irq_gpio) {
                int i;
 
+               cmd.read_write = 0;
                cmd.function = 1;
                cmd.address = 0x04;
                cmd.data = 0;