The check for column exclusion did not verify that the event being
checked was an L2 event, and not a software event.
Software events should not be checked for column exclusion.
This resulted in a group with both software and L2 events sometimes
incorrectly rejecting the L2 event for column exclusion and
not counting it.
Add a check for PMU type before applying column exclusion logic.
Fixes: 21bdbb7102edeaeb ("perf: add qcom l2 cache perf events driver")
Acked-by: Mark Rutland <mark.rutland@arm.com>
Signed-off-by: Neil Leeder <nleeder@codeaurora.org>
Signed-off-by: Will Deacon <will.deacon@arm.com>
}
if ((event != event->group_leader) &&
+ !is_software_event(event->group_leader) &&
(L2_EVT_GROUP(event->group_leader->attr.config) ==
L2_EVT_GROUP(event->attr.config))) {
dev_dbg_ratelimited(&l2cache_pmu->pdev->dev,
list_for_each_entry(sibling, &event->group_leader->sibling_list,
group_entry) {
if ((sibling != event) &&
+ !is_software_event(sibling) &&
(L2_EVT_GROUP(sibling->attr.config) ==
L2_EVT_GROUP(event->attr.config))) {
dev_dbg_ratelimited(&l2cache_pmu->pdev->dev,